Evans Piling, together with our colleagues at Metpro Europe Limited, can offer a large range of steel pipes for tubular piling both from stock as well as fresh production, details of the size range offered is shown below.
Supply condition | Size range | Wall thickness | Typical lengths |
---|---|---|---|
Longitudinal Welded (ERW/HFI) | Up to 610 mm | Up to 20 mm | 15 m max. |
Longitudinal Welded (UOE) | 610 – 1118 mm | Up to 50 mm | 12 m max. |
LDSAW (3 roll bender) | 610 – 2540 mm | Up to 38 mm | 12 m max. |
LDSAW (3 roll bender) | 1117 – 4000 mm | Up to 110 mm | 6 m max. |
LDSAW (4 roll bender) | 900 – 5000 mm | Up to 110 mm | 4.1 m max. |
Spiral DSAW | 508 – 3000 mm | Up to 25.4 mm | Up to 50 m |
* Longer lengths can be supplied by circumferential cross welding, including weld integrity testing.
We can also supply piles with additional fabrication options such as stiffening plates, interlocks, coatings, and more.
Useful Formulae
Weight: (OD – WT) × WT × 0.0246615 = kg/m
Freight Factor: (OD / 1000)² × (1000 / kg/m) = m³/tonne
Section Modulus: (OD⁴ – ID⁴) / 32000 = cm³/m
Moment of Inertia: (OD⁴ – ID⁴) / 64000 = cm⁴/m
For all calculations, show OD and ID in millimeters.
OD = Outside Diameter
ID = Inside Diameter
WT = Wall Thickness